Tuesday, June 6, 2017

Yes, You Do Need an ESD Wastebasket

Originally posted as The Cause for ESD Wastebaskets by Transforming Technologies - Re-posted here, including slight edits, with permission

It is fair to wonder why there is a need for ESD wastebaskets. If the basket resides underneath a workstation, and stays there permanently, the need may not exist.

 However, there are a number of circumstances when the wastebasket could present a significant hazard to electronic products. The following are just a few examples of potentially risky scenarios:

Worksurface Cleaning: An operator lifts the wastebasket to the edge of the workstation to collect the debris being removed. Should a static-sensitive product be present on the worksurface and not contained in a shielding container, there is a good opportunity for exposure to electrostatic fields that exceed safe limits.

Lead Trimming/Board Cleaning Operations: When trimming component leads or using aerosol cleaners on PCBs (Printed Circuit Boards), some operators will hold the PCB over a wastebasket to catch the clippings or solvent run-off. Many times, the PCB will be placed well into the waste container to assure catching the unwanted materials. This operation puts PCBs and ESD-sensitive devices very close to potentially significant electrostatic fields.

Aisle Proximity: Some wastebaskets have been observed in close proximity to production floor aisles, where product transfer carts pass or may be parked. ANSI/ESD S2020 requires items that generate 2,000 volts or more (measured at 1” from the item) be kept at least 12” from ESD-sensitive devices. Using ESD wastebaskets eliminates the risk of carts being parked next to static-generating baskets.

While company ESD policies may prohibit some of the actions mentioned above, it does not mean that they will not occur from time to time. ESD wastebaskets provide assurance that the wastebasket will never be an ESD threat to your product.

Transforming Technologies offers ESD wastebaskets in static-dissipative polypropylene and in stainless steel for cleanroom operations. If a liner is to be used for easier maintenance, Transforming Technologies offers them in both conductive and static dissipative.

Please visit QSource.com for further information about these Transforming Technologies products:

28-Quart, Black ESD-Safe Waste Basket (WBAS 28)
  • Material: Carbon-loaded, black conductive Polypropylene
  • Point-to-Point Resistance RP: 104- 105 W
  • Height: 15"
  • Opening: 13.5" x 9.5"
22-Gallon, Black ESD-Safe Waste Basket (WBAS90)
  • Weight: 7.5 lb.
  • Dimensions: 30" x 20" x 11"
  • Material: Carbon-loaded, black conductive polypropylene
  • Resistance - RTP: 104 - 105
  • Marking: Yellow ESD symbol
44-Gallon, Black ESD-Safe Waste Basket (WBAS180)
  • Weight: 13 lb.
  • Dimensions: 31" x 24" x 24"
  • Material: Carbon-loaded, black conductive polypropylene
  • Resistance - RTP: 104 - 105
  • Marking: Yellow ESD symbol
2-Mil, 7-10 Gallon Pink Dissipative Anti-Static Trash Liners (WBASLP)
  • Basic Material: Single layer of non-amine polyethylene
  • Size: 24" x 24"
  • Tensile Strength: 2,000 to 3,000 PSI
  • Tearing Strength: 65- to 450-lb. per square inch
  • Surface Resistivity: ‹ or equal to 1011 ohms/sq.
  • Static Decay Rate: 5 kV - 0 volts ‹ 2 seconds per
  • Shelf Life: Permanently anti-static under normal storage conditions
3 Mil, 7-10 Gallon Black Conductive Trash Liners (WBASLB)
  • Basic Material: Single layer of non-amine polyethylene
  • Size: 24" x 24"
  • Tensile Strength: > 2,000 PSI
  • Tearing Strength: > 400-lb. per inch
  • Surface Resistivity: ‹ 30,000 ohms/sq
  • Volume Resistivity: ‹ 30,000 ohms/cm
  • Shelf Life: Permanently anti-static under normal storage conditions
22-Gallon, Black Conductive ESD Trash Can Liners (WBAS22LB)
  • Basic Material: Single layer of non-amine polyethylene
  • Thickness: 3 mil
  • Size: 24" x 24"
  • Volume: 7-10 gallon (28-40 quart)
  • Tensile Strength: > 2000 PSI
  • Tearing Strength: > 400-lb. per inch
  • Surface Resistivity: ‹ 30,000 OHMS/sq
  • Volume Resistivity: ‹ 30,000 OHMS/cm
  • Shelf Life: Permanently anti-static under normal storage conditions
22-Gallon, Pink Dissipative ESD Trash Can Liner (WBAS22LP)
  • Basic Material: Single layer of non-amine polyethylene
  • Thickness: 3 mil
  • Size: 24" x 24"
  • Volume: 7-10 gallon (28-40 quart)
  • Tensile Strength: > 2000 PSI
  • Tearing Strength: > 400-lb. per inch
  • Surface Resistivity: ‹ 30,000 OHMS/sq
  • Volume Resistivity: ‹ 30,000 OHMS/cm
  • Shelf Life: Permanently anti-static under normal storage conditions
44-Gallon, Black Conductive ESD Trash Can Liner (WBAS44LB)
  • Basic Material: Single layer of non-amine polyethylene
  • Thickness: 3 mil
  • Size: 24" x 24"
  • Volume: 7-10 gallon (28-40 quart)
  • Tensile Strength: > 2000 PSI
  • Tearing Strength: > 400-lb. per inch
  • Surface Resistivity: ‹ 30,000 OHMS/sq
  • Volume Resistivity: ‹ 30,000 OHMS/cm
  • Shelf Life: Permanently anti-static under normal storage conditions
44-Gallon, Pink Dissipative ESD Trash Can Liner (WBAS44LP)
  • Basic Material: Single layer of non-amine polyethylene
  • Thickness: 3 mil
  • Size: 24" x 24"
  • Volume: 7-10 gallon (28-40 quart)
  • Tensile Strength: > 2000 PSI
  • Tearing Strength: > 400-lb. per inch
  • Surface Resistivity: ‹ 30,000 OHMS/sq
  • Volume Resistivity: ‹ 30,000 OHMS/cm
  • Shelf Life: Permanently anti-static under normal storage conditions

Tuesday, February 14, 2017

How Well Is Your ESD Flooring and Footwear System Working? – Guest Blog

Figure 1: System Resistance Test
by Craig Zander, Transforming Technologies

Craig’s latest Q Source Resource Guest Blog looks at how a Walking Voltage Test reveals how well your ESD flooring & footwear system is working.

The ESD flooring and footwear system is an effective way to ground people that need to be on the move in a factory. ESD footwear, when worn properly, is designed to drain the voltage from a person to the floor and then to ground. Periodic testing of both the floor and the footwear is required to verify proper functioning.

Until recently, a System Resistance Test (ANSI/ESD STM97.1) was all that was needed to qualify an ESD control flooring and footwear system. If the resistance was less than 35 megohms, it was assumed that the person’s voltage would not exceed 100 volts (the upper limit for ANSI/ESD S20.20). However, this testing is done with the person stationary and having both feet flat on the ground. What happens when the person starts moving and the entire foot is not making contact with the floor?


Figure 2: The Walking Test Pattern
The most recent version of ANSI/ESD S20.20 now requires a Walking Voltage Test (ANSI/ESD STM97.2) be performed when qualifying flooring and footwear systems. The test consists of measuring body voltage generated during a six-step pattern used to simulate moving throughout a facility. This test will determine the actual voltage on the person while moving. Research has shown that when tested separately, ESD floors and footwear systems may pass the resistance test, but when used together, can greatly exceed the 100-volt threshold.


Determining the maximum voltage generated by people moving on the factory floor is very valuable information. By knowing the maximum voltage generated you will know that your flooring and footwear investment is performing as designed. You may also be pleasantly surprised to find out that the system is working quite well and you are able to handle devices with much lower Human-Body Model (HBM) damage thresholds.

WT5000

Equipment is available to accurately measure and record the walking voltage. One such instrument is the WT5000. The WT5000 Walking Test Kit (Warmbier WT5000 Electrometer Walking Test Kit) measures and records the walking voltage while providing a graphical readout. The instrument connects to a PC using any Windows version for easy data collection. The WT5000 identifies the peak voltages per the requirements in the standards.

The two-in-one EFM51WT (Transforming Technologies 7100.EFM51.WT Warmbier EFM51WT Field Meter Walking Test Kit) meter holds the PEAK value of the measured body voltage, as well as the LIVE static voltage measured on the operator’s body. The kit includes the EFM51 static field meter, walking test adapter plate, hand probe and conductive carrying case. The EFM51 is a fully functional field meter that, in addition to the Walking Test, measures and detects electrostatic fields, surface potentials, and discharge times (with optional charge plate accessory (part number 7100.EFM51.CPS.SET).

EFM51
You have made the investment in an ESD flooring and footwear system so that people can be mobile while still protecting your products from ESD events. Determining your actual walking voltage generated is critical to knowing that your products are being protected.

CLOSING: Thanks, Craig! We appreciate you filling us in about the necessity of Walking Voltage Tests to ensure proper ESD protection for flooring and footwear systems. Your expertise is invaluable to our Q Source community.

For information about Transforming Technologies and their ESD control/monitoring products (including walking test kits), please visit QSource.com. you.

Thank you for reading. Please leave your comments, questions, and suggestions for us by clicking on “Post a Comment.” We also encourage you to share this post via the social media icons below.

Subscribe to our email newsletter for additional Q Source product information, reviews, how-to articles, and special offers.

Monday, August 29, 2016

Seven Steps to Creating an Ergonomic-Rich Working Environment - Guest Blog

by Carissa Harris, Marketing Communications Coordinator, Sovella, Inc.

In Carissa’s first Guest Blog for the Q Source Resource, she focuses on how you can create an ergonomic workspace.


Proper ergonomics play a vital role in workplace productivity.
When it comes to productivity and efficiency in the workplace, proper ergonomics play a vital role. A workplace that focuses on the well-being of their employees will find an increase in their output, leading to greater profit. Ergonomics is about more than just posture and arm reach. It takes into consideration all aspects of a worker’s movement, eyesight, noise level, and more. By having all components and areas in easy reach and at comfortable distances, it minimizes the amount of bending, twisting, and reaching workers need to make, and consequently reduces strain, stress, and discomfort, leading to a more relaxed positions and greater efficiency.

Here are seven steps that can guide you in creating an ergonomic-rich environment at your company:
  1. Research and Develop a Plan of Action – Implementing a proper, ergonomic workplace requires research into the correct products for your company and your employees. Understanding the fundamentals of ergonomics will help when it comes time to selecting the best products for your environment. Creating a plan of action ahead of time will also reduce the risk of purchasing products that will not benefit employees in the long-term. It can be beneficial to look to other companies with ergonomic environments and see how you might replicate their successes.
  2. Conduct Interviews with Employees and Observe Their Behaviors – To see where you have fallen short in the past, conduct interviews with employees and review any prior injury reports. This will provide the insight into the current problems and assist you in purchasing the right equipment in the future. Some risk factors in ergonomic-poor workspaces include: awkward postures, over-exertion, straining eyes, poor ventilation, and improper lighting. These can lead to worker injuries, including carpal tunnel syndrome, muscle cramping, slipped discs, and tendinitis. Understanding these risks and injuries will lead to better purchasing decisions and happier staff.
  3. Gather the Team – Getting everyone on board will make the transition to ergonomics smoother and quicker. Employees will be open to the change when they are informed of the benefits, including less stress and strain.
  4. Consider the Not-So-Obvious –
    • Should employees be sitting or standing for their particular work? Or given the option for both? Tasks with little lifting or reaching may benefit from sitting with the option to stand, while jobs that require heavy-lifting, continuous movement, or parts retrieval will benefit from standing with the option to rest. Height-adjustable benches and proper seating are essential.
    • Is the bench surface correctly positioned and does it cater to various heights? Body size and leg space are factors to consider.
    • Which style of chair is best? Comfort and adjustability are important in choosing the best chair for the job. A chair that is ergonomic will be adjustable to accommodate all body types.
    • Are the monitors in the correct position? Consider viewing angle and distance. Screens should be well lit and in focus to prevent strain on the eyes.
    • How does lighting affect work? Shadows, brightness, even color of light can affect the well-being of employees. Proper lighting can prevent headaches and fatigue.
    • Consider keyboard distance, reach distance for tools, placement of equipment, ventilation, etc. Managers should also encourage good posture and breaks to avoid strain, tension, and fatigue, as well as stretching. Remember, all employees are not created alike, and body type should be taken into account.
  5. Be Sure Vendors Can Meet Your Ergonomic Needs – Choose furniture that can be properly adjusted and explore customizations to best suit your employees. Vendors should be able to demonstrate the functionalities, calculate benefits, and give references. Think about long-term use, and pick a sustainable option. Select a vendor that provides the best solution in a timely manner, with the best support.
  6. Happiness is the Goal – Quality workspaces make for happier employees. If they feel better, they will perform better, in turn boosting your productivity and profitability. Ergonomic-rich environments have employees that take fewer sick days, report fewer injuries, and are over-all more satisfied.
  7. Measure and Improve – Understand how employing ergonomics has improved productivity, reduced injuries, and created a happier staff. Compare output before and after, and survey your employees to determine any improvement and increased happiness. It is important to evaluate the workplace and make improvements as needed. By continuing to improve, you will continue to develop a better system that continues to function and produce at the highest possible level, founded upon proper, modern ergonomics.
An ergonomic-friendly workstation project takes an initial investment of research time, budget, customization, and more, but turns those investments into an opportunity for business growth. By using baseline data and key performance indicators (KPIs) to analyze your investment decision (both before and after), you’ll be able to justify the effect ergonomics has on employees and their work. You can also start small and increase investments with proven results paving the way to continue.

Great tips, Carissa! Thank you for providing a solid plan to implement ergonomics into the working environment. We look forward to learning more about the topic and how Sovella can assist in such an implementation.

For information about Sovella ergonomic workspace products, or to place an order, please visit QSource.com. You may also contact us via email or phone at 800-966-6020 and we will be happy to assist you.

Thank you for reading. Please leave your comments, questions, and suggestions for us by clicking on “Post a Comment.” We also encourage you to share this post via the social media icons below.

Subscribe to our email newsletter for additional Q Source product information, reviews, how-to articles, and special offers.

Friday, July 22, 2016

Using ACL 7600 IPA Wipes in Conjunction with ACL 8690 Acrylic Conformal Coating for PCB Rework/Repair Prep – Guest Blog

by Steve Allen, VP Marketing and Innovation, ACL Staticide

In Steve’s latest Guest Blog for the Q Source Resource, he recommends a process of PCB preparation for rework/repair.

Preparing PCBs (printed circuit boards) for rework or repair is a very important process. ACL Staticide has developed and manufactures an array of precision cleaners and surface preparation products, along with final finishing conformal coats to aid in this application. These products’ primary focus is in the area of printed circuit board repair and OEM manufacture. Let’s cover some key areas of PCB rework and repair using a two-step process for surface preparation and finishing.
In many instances of PCB repair, surface preparation with a pre-saturated wiper followed by treatment with conformal coating is the process of choice for reworking a board and getting it back into service.

With that in mind, ACL’s 7600 IPA Wipers are perfect for surface preparation following repair. The 7600 is a pre-saturated wipe using a precise 70/30 blend of extremely pure, electronics-grade isopropyl alcohol blended with deionized water to prevent premature evaporation of the cleaning solvent. The solvent is added to the wiper in a cleanroom environment. These wipers use a non-woven Sontara® technology designed to be extremely low linting, even at the perforation. Available in a 100-wipes reclosable container (made of non-hazardous material), the 7600 product is perfect for final finishing work of any circuit board. It is great for removal of hand oils, conductive greases, carbonized soils, dust/dirt, light flux residues, and a variety of other soils.

A 2-wiper use process is recommended for general-purposed cleaning and hand wiping of larger components and various board surfaces. One wipe is used for initial cleaning of heavier residues, and a second wipe for final surface cleaning and finishing. All surfaces should be allowed to gently dry for one to two minutes, or dry using compressed air or a duster product like the ACL 8640 Turbo Blast Duster.



Following this process, the board is prepared and ready for application of surface protection like acrylic conformal coating. ACL’s 8690 Acrylic Conformal Coating is the product of choice for protecting the PCB and all surface components from oils, moisture, and most soils. It is used following surface cleaning and preparation with the 7600 IPA wipers. ACL 8690 can be applied to the entire board surface. It is dry to the touch in less than 30 minutes and completely cures in 24 hours. It provides protection as well as heat resistance and contains a UV dye indicator so that the user can be sure the entire board and all components have been treated. ACL 8690 leaves behind a high-gloss cure (making it suitable for final presentation to the customer at contract manufacturers) and prepares the board for final installation.

This process of using both the 7600 wipes and 8690 conformal coating in conjunction with each other for final board preparation and final surface finishing prior to installation helps eliminate potential failures and damage to PCBS or devices. Please contact us with related questions or comments.

Thank you, Steve! That sounds like the way to go when preparing printed circuit boards. We look forward to your future articles.

For information about , or to order, any of the ACL products mentioned in this blog, please visit QSource.com. You may also contact us via email or phone at 800-966-6020 and we will be happy to assist you.

Thank you for reading. Please leave your comments, questions, and suggestions for us by clicking on “Post a Comment.” We also encourage you to share this post via the social media icons below.

Subscribe to our email newsletter for additional Q Source product information, reviews, how-to articles, and special offers.

Wednesday, June 8, 2016

What You Need to Know When Selecting ESD Flooring – Guest Blog

by Craig Zander, Transforming Technologies

Craig’s newest Guest Blog, for the Q Source Resource, provides valuable tips about selecting ESD flooring for your workplace


The use of ESD flooring and footwear is a popular way to ground people working with ESD-sensitive devices that cannot use a conventional wrist strap/cord system because they need to be mobile, or because they are working near equipment with moving parts that could pose a hazard. ESD footwear and flooring provide a convenient method to drain the charge from the operator to ground.

There are many options for ESD flooring that are “permanent” solutions, such as conductive tiles and epoxies. These products generally have very good durability and can last for many years. Unfortunately, they also present a few challenges.

PERMANENT ESD FLOOR CHALLENGES


  • Cost: ESD floor tiles and epoxies are an expensive option. The cost of the tiles or epoxy in combination with the conductive undercoat and installation expense makes permanent flooring one of the more expensive options.
  • Moisture: In some cases, the moisture content in the sub-floor is too high to allow successful or long-term adhesion. Hydrostatic pressure from floors can cause tile lifting or epoxy bubbles. Testing must be done prior to installation to be sure that the floor can be installed.
  • Installation: Installing an ESD tile or epoxy floor requires experienced installers. The conductive undercoat must be applied in a precise quantity and manner. Mistakes can lead to poor adhesion and poor electrical readings on the installed floor.
  • Maintenance: While new floors may look amazing shortly after installation, they must be maintained to keep their appearance and their electrical performance. Some floors require certain floor finishes, and some floors cannot be waxed or their electrical properties will become diminished.
  • Permanence: While a permanent floor can be an advantage, it may be a disadvantage to companies that occasionally change facility layouts or to companies that lease space.

TEMPORARY OR PORTABLE ESD FLOORING

There are a number of options for those that need to ground their operators through footwear and flooring, but do not want a permanent ESD floor.

ESD Mats

ESD mats come in a variety of options including size, thickness, contour, and conductivity. ESD mats are generally placed in front of standing operations and provide a path to ground for the operator and, possibly, a more ergonomic standing surface than the standard floor.



Floor mats may be offered in specific sizes (i.e., 2’ x 3’, 3’ x 4’, etc.), or may be offered with interlock to provide a variety of lengths. They are easy to relocate should production equipment need to be moved.

ESD Runners

ESD floor runners offer a solution in front of long assembly lines, or areas where mobile equipment is being used and needs to be grounded.



ESD floor runners are generally smooth or slightly textured to allow mobile equipment to move, thus they offer less ergonomic benefit than mats.

Interlocking Tiles

ESD interlocking tiles provide an effective way to cover a larger area, or an entire floor, while still offering some portability. The tiles can be easily cut to fit an area and they are free floating on the floor so there are no moisture issues that come with permanent floors. Many of the interlocking tiles also provide ergonomic properties. Yellow safety edges are also available if the floor does not terminate at a wall.



CHOOSING THE RIGHT FLOOR

Whether you select permanent flooring or temporary/portable ESD flooring, you need to verify that the electrical properties of the footwear and flooring combination will meet your requirements.

To be in compliance with ANSI/ESD S20.20 you must verify two specific measurements. First, you need to measure the resistance of the person, through the footwear, through the flooring and to ground (ANSI/ESD STM 97.1 Floor Materials and Footwear – Resistance Measurement in Combination with a Person). Second, you need to verify the voltage being generated by people using your selected footwear (shoes or foot grounders) and flooring (ANSI/ESD STM 97.2 – Floor Materials and Footwear – Voltage Measurement in Combination with a Person).

ANSI/ESD STM97.1 (Warmbier Metriso 3000 Resistance Meter)


ANSI/ESD STM97.2 (Warmbier WT-5000 Walking Test Kit)



We’ve briefly reviewed the factors to be considered when choosing ESD flooring. With these in mind, you can select the floor that meets your needs for ESD properties, overall cost, and ease of use.

Thanks, Craig! That’s excellent information to assist our readers in choosing the proper ESD flooring solution to meet their needs. We’re excited for the next time you share your expertise with our Q Source community.

For information about Transforming Technologies and their ESD control/monitoring products, please visit QSource.com. You may also contact us via email or phone at 800-966-6020 and we will be happy to assist you.

Thank you for reading. Please leave your comments, questions, and suggestions for us by clicking on “Post a Comment.” We also encourage you to share this post via the social media icons below.

Subscribe to our email newsletter for additional Q Source product information, reviews, how-to articles, and special offers.

Wednesday, January 13, 2016

Looking Good, Feeling Good: Microscope Ergonomics Is Much More Than Sitting Comfortably – Guest Blog

by Stephen Sanderson, International Product Manager, Vision Engineering


In Stephen’s first Guest Blog for Q Source, he discusses microscope users’ injuries and discomfort and ways to remedy these issues.

Headaches are a common complaint of microscope users.
Ask any seasoned microscope user about working with microscopes and they will often have stories of sore necks, headaches and “microscope eye,” seemingly caused by leaning over conventional stereo microscopes for prolonged periods. Such issues not only have a significant effect on users’ comfortable working, but their discomfort also affects concentration and, by association, the ability to perform tasks.

They are not alone, in a report of microscope users from the Federal Institute of Industrial Safety:
  • 33% reported stiffness and pain in movement
  • 60% experienced headaches
  • 40% had eye complaints
While it is hard to attribute every incidence of each complaint with the microscope, it is often the common factor. Specific attention can also be paid to eyepieces. Most conventional stereo microscopes produce a very small and bright exit pupil that requires the user to maintain a fixed viewing position very close to the eyepiece. This leads to areas of poor ergonomics, poor postural ergonomics, and poor optical ergonomics.

The requirement for a fixed viewing position can be helped by ensuring that the user’s workstation is correctly configured. To do this work from the ground up, adjust the user’s seat and bench height, have them stand and sample the position so that the final location of the eyepieces does not require the user to overextend or compress the neck. Don’t forget that it is often possible to raise either the sample or the entire stand, if needed. That dusty old text book that sits in the corner unused could be just what is needed to lift the sample to a better working height.

For optical ergonomics with eyepiece microscopes the situation is more complicated. Interpupillary distance, diopter adjustment, and eyepiece selection all sound complicated and can factor in the user’s comfort affecting eyestrain and headaches. The answer? Get rid of the eyepieces.

NO EYEPIECE = GREATER COMFORT & PRODUCTIVITY

Eyepiece-less systems, such as Vision Engineering’s Mantis and Lynx ranges, are designed with ergonomics at their core. Rather than small, restrictive exit pupils of conventional eyepieces, Mantis and Lynx ranges offer exit pupils that are up to 10 times larger. Those allow users freedom of movement and a natural comfortable working position.

Vision Engineering's Lynx Microscope is ergonomically
designed for user comfort and freedom.
When eye comfort is increased, by reducing refocusing and iris activity through a working position that is further from the microscope itself, it allows an equidistant direct view of the subject and inclusion of ambient light into the field of view. Where eyesight correction is necessary, the user can simply use their own spectacles allowing correction for conditions such as astigmatism that cannot be corrected through eyepieces.

Good ergonomics lead to comfortable users who are better able to concentrate for longer are less prone to illness or injury, and who experience ease of operation and enhanced ability to perform a task. More importantly, for many users it means that they can go home at the end of the day happy and pain free with the satisfaction of a job well done.

In conclusion, consider ergonomics when choosing your next microscope system to reduce user injuries, increase productivity, and ensure that users are at their best on the job.

Thank you, Stephen, for those valuable insights into creating a safer, more comfortable environment for microscope users. We look forward to future Guest Blogs from you and Vision Engineering.

For information about Vision Engineering's microscope/inspection products, please visit QSource.com. You may also contact us via email or phone at 800-966-6020.



For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.


Thursday, November 19, 2015

How to Choose a Continuous Monitor for Your ESD Control Program – Guest Blog

by Craig Zander, Transforming Technologies

In Craig’s latest Guest Blog for Q Source, he provides tips for how to choose a continuous monitor for your ESD control program

The first step in a quality ESD control program is grounding your personnel. People walking in a facility and performing common tasks generate a static charge. If not grounded, the voltage accumulated through this charging may be transferred to your product and can cause significant or catastrophic damage to electronic devices.

The most common method for grounding people handling electronics is by using a wrist strap and coil cord. The wrist strap and cord transfer any voltage from the person to ground. When a wrist strap system is functioning correctly and worn properly, it is extremely difficult to accumulate more than a few volts on a person, which, in all but the most extreme cases, is not enough to cause damage to devices.

Wrist strap systems should be tested on a regular basis.
If the wrist strap system is malfunctioning or worn improperly, the voltage may continue to grow and accumulate to levels that can damage most electronic devices. Therefore, it is very important that the wrist strap system be tested on a regular basis to assure that it is functioning properly.

There are a number of ways that the wrist strap system can be tested, and the best method depends on the number of employees in the facility, the critical nature of the product (i.e., medical, aerospace, military, high value), and budget.

One of the most common methods for verifying wrist strap performance is the wrist strap/footwear test station. The test station(s) is placed near the entrance to the ESD Protected Area (EPA) and employees test their wrist strap to verify its operation before they are allowed to enter the EPA. The testers have a wide range of capability and costs. Some testers have a simple pass/fail indicator while other testers have digital readouts and data logging capabilities to record the test results for each employee. While these testers meet the requirements of regular testing of the wrist strap, there are a number of potential drawbacks:

  • Test Frequency: How often the person goes to the test station varies between companies. Some companies require testing at the beginning of each shift while others test every time the person leaves the work station for breaks. In each case, should the test indicate a failure of the wrist strap, there leaves a question as to when the failure occurred and how much product was handled with the failed strap. For high reliability and value products the customers of this company may want to know the disposition of the product that was handled during the time between tests.

  • False Security: When testing a wrist strap at a test station, only the wrist strap, cord, and person are tested at that precise moment. The situation could change once the operator reaches the work station. The operator could adjust the strap after testing, the resistance could increase due to dry skin conditions, or the ground jack at the work station could malfunction. All of these scenarios could lead to high voltage accumulation on the operator that would not be detected by the tester.

  • Wasted Time: Depending on the size of the company, there can be a line at the test station of employees waiting to test their wrist straps, effectively delaying the time they spend on productive activities.

  • Record Keeping: Most companies require their people to sign-in at the tester and record the results. There are some systems that automatically record and store the results after the employee has swiped their ID badge. Someone in the company still must maintain and review the test records to assure that everything is working as designed, which can be tedious and time-consuming.

To address these drawbacks, many companies are now using continuous monitoring to verify that the wrist straps are functioning correctly. Continuous monitors are located at the work station and provide an audible and visual indication when the wrist strap system malfunctions. Once the operator hears the alarm they do not touch the product until the problem is resolved and the system is functioning correctly. With continuous monitoring systems, you avoid waiting in line for testers, eliminate the extensive record keeping, and you remove doubt that the product may have been handled by an ungrounded operator. There are no more decisions to be made on what to do with product that was handled by ungrounded operators, as there is no longer any time between tests.

There are a few options available today for continuous monitoring. Some monitors will simply verify the operator wrist strap, while others will verify the wrist strap, the work surface ground, and possibly other equipment grounds.

Capacitance/Impedance Monitors

Some continuous monitors use capacitance or impedance to verify that the operator is connected to the system. These systems allow the company to use the standard single-wire wrist strap and coil cord system and are typically the lowest cost option for continuous monitoring. These monitors operate by using a capacitance or impedance circuit to estimate the resistance of the operator wearing the wrist strap. Since the system is not making an actual resistance measurement, these systems can sometimes be fooled by high skin resistance of the operator and may provide false passes.

Dual Conductor Resistance Monitors

Dual conductor resistance monitors use a special wrist strap and coil cord to incorporate the operator in a resistance measurement. Instead of the single conductor wire found on standard wrist straps, this monitor uses a dual-wire coil cord and a wrist strap that has two isolated halves. A voltage is sent down one of the wires and into the wrist strap. When the person is wearing the wrist strap properly, their skin completes the circuit and the signal returns down the second wire to the monitor. This system assures that the operator is electrically connected to ground.
Many companies are now using continuous monitors like Transforming Technologies Ranger Series.

While dual conductor resistance monitors provide the most reliability, they also typically have the highest cost and require special wrist straps. A new series of dual-wire resistance monitors (from Transforming Technologies) are priced closer to the single-wire systems, but provide the reliability of dual wire. The CM1601 Resistance Ranger provides dual wire monitoring for a single operator, and the CM1602 Dual-Wire Resistance Ranger monitors the operator and one work surface ground. Transforming Technologies also offers great options for dual-wire wrist straps and cords that provide both excellent quality and value.

Thanks, Craig, for further educating us on how to develop and maintain a successful ESD control system. We look forward to your future Guest Blogs.



For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Tuesday, October 6, 2015

The Importance of Testing & Monitoring Your ESD Grounding Devices – Guest Blog

by Craig Zander, Transforming Technologies

In Craig’s debut Guest Blog for Q Source, he explains the importance of testing and monitoring of ESD grounding devices.

Transforming Technologies PDT 800K Test Station
The first line of defense for protecting electronic devices and assemblies from damage due to Electrostatic Discharge (ESD) is to properly ground all personnel that come in contact with the product. When a person is effectively grounded, all of the voltage that accumulates on their body when moving rapidly travels to ground before it can affect the product.

The most common and reliable method for grounding operators is the wrist strap and coil cord combination. The conductive materials inside the wrist band contact the skin and transfer the voltage from the operator through the cord and to ground. When worn correctly, and tested or monitored, wrist straps are the preferred method for grounding people.

When grounding a person through a wrist strap, ANSI/ESD S20.20 requires the resistance of the person to equipment ground to be less than 3.5 x 107 ohm (35 meg ohm). Typically, the resistance to ground of a person properly connected with a wrist strap is just over 1 meg ohm (the value of the resistor in the cord assembly).

Wrist strap and coil cord assemblies need to be tested or monitored regularly. Some companies chose to test the wrist strap system one or more times per day at central testing stations (for example, the PDT 800K Test Station). Other companies opt to continuously monitor (using a device such as the CM1602 Constant Monitor) the wrist strap connection so that product is not handled if the grounding system fails.
 
Transforming Technologies CM1602 Constant Monitor
There are situations, however, when being connected to a ground jack via a cord is not conducive to efficient or even safe operation. Operations that involve frequent transportation of product within the facility, as well as operations that involve machinery, present a challenge to the wrist strap and coil cord grounding method. In these cases, factories may use a combination of conductive flooring and foot grounders to effectively ground the operator.

The requirements for grounding a person through flooring and footwear have changed in the ANSI/ESD S20.20 2014 Standard. Previous versions of ANSI/ESD S20.20 provided you with two options. If the resistance from the person through the footwear, through the floor and to ground was less than 35 megohm, no further testing was necessary. If the resistance was greater than 35 megohm, you could still meet the requirements of the standard if the resistance was less than 1.0 x 109 ohms and you can demonstrate that the operators generate less than 100 volts. The latest version of S20.20 (ANSI/ESD S20.20-2014) requires the resistance test and the walking voltage test for qualifying flooring and footwear materials together. While many flooring and footwear options may pass the resistance test, it has been discovered that some combinations of floor materials and foot grounding materials do not work well together.

To test the walking voltage generation of flooring and footwear systems you use ANSI/ESD STM 97.2 Floor Materials and Footwear - Voltage Measurement in Combination with a Person. This test involves recording the voltage of a person while they perform a repetitive walking pattern. To record the voltage you can use a charge plate monitor with data recording capability, or a similar instrument with the same specifications listed in the test method.

Body voltage measurement test set-up.
The new software “Digilloscope”
can mark the five highest
peaks automatically and calculate
the average value.
Transforming Technologies developed the Warmbier WT5000 Walking Test Kit to meet the needs of the ANSI/ESD STM 97.2 test. The WT5000 is a battery-operated instrument that is easily transported to various areas of the factory floor. The system includes the trademarked data acquisition and analysis software “Digilloscope for Windows™.”

The WT5000 records the voltage on the operator while they are performing the walking steps called out in the standard. Once several repetitions of the pattern are complete, the software will provide the peak voltage and average value. The data is used to confirm compliance to standards and to determine the lowest possible voltage device (Human Body Model Discharge Threshold) that can be handled in the facility.

Thanks for that very important information about ESD control and testing, Craig. We look forward to future Guest Blogs to learn from your expertise.




For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Tuesday, April 14, 2015

Flux Cleaning Myths: The Basics - Guest Blog

by Steve Allen, VP Marketing and Innovation, ACL Staticide
 

In Steve’s latest Guest Blog he focuses on a few myths about flux cleaning

There are many myths and misunderstandings about cleaning solder flux from printed circuit boards. Let’s address some of those primary PCB cleaning & preparation myths and concerns for a variety of rework and repair operations.

To begin, we clean and remove most flux residues to prevent metal oxidation and generally poor electronic circuit connections.

Technologists and technicians alike are often advised to clean boards post-soldering processes with isopropyl alcohol (i.e., IPA). But there are proven chemical reasons for not using a hygroscopic solvent like IPA (hygroscopic solvents draw moisture from the air to themselves as an equilibrium mechanism) for basic board cleaning and further process preparation.

In most instances, IPA is too aggressive for most plastics and can intrude into parts and spaces creating undesirable effects. IPA is known to dissolve polystyrene and other types of plastic capacitors. By dissolving various materials, a potential low-ohm and conductive film is spread over the surface of the PCB while the flux itself (typically a very high solids material) is left untouched in a host of board surface areas, and in particular, at the solder joints. Leftover flux materials can be detrimentally conductive in many instances.

A LOOK AT FLUX MATERIALS

Rosin-based flux is generally not conductive unless it is baked on at extremely high temperatures (caramel or black in color). Generally, no-clean flux is just that. It does not always require cleaning and you may leave it on. Many low-solids flux materials, when applied under a correctly controlled process, will completely evaporate with time. Most water-soluble fluxes need to be removed simply because they leave behind a soap-scum-like residue, which is generally conductive.

Additionally, there are some very aggressive fluxes like RA that must be removed as they contain very acidic substances. RMA is the most prevalent rosin flux (RMA rosin = mildly activated and RA rosin = less activated). It is actually not the rosin that performs the flux activity, but another substance in the flux compound, which promotes spreading and adhesion. The basic rosin material is simply a carrying vessel for the active flux ingredient.

FLUX WORKS ON TWO FRONTS

When activated (and temperature controls this; most fluxes kick in around 100° C or 212° F), flux is a very reactive element that wants to bind with oxygen molecules. It is so reactive it can strip oxygen molecules that have already bonded with copper. So, it converts copper oxide back into basic copper. The second thing flux does is lower the surface tension of the solder. This lets the solder flow over the soldered surface, spread, and adhere.

Under a correctly controlled process, the flux is given some time to activate and do its work before solder is applied. Wave solder machines apply warm flux to the board first, then let it soak for a few seconds as the conveyor moves over a warming plate, and finally the flux is fully activated. The board then passes through the solder wave where the flux totally evaporates and essential leaves behind a clean board.

Solder paste works in a similar way. When conducting reflow processes, you have a ramp up to flux activation, a hold phase to let the flux do its work and evaporate, and finally, a ramp up to liquid phase where the solder melts and flows on the remaining flux. In theory, if reflow operations are done correctly, there should be minimal flux residue and board washing is simple or may not be required at all.

Boards that have been reworked (e.g., manually touching one individual component) will have residue and require washing with flux removers. The flux in solder wire is a different composition than the flux found in pens or liquid form. The flux in solder wire is dry powder and is more aggressive than paste as it has a shorter time to do its work.

Plus, there are specially formulated fluxes like the gel fluxes or tacky fluxes. These are formulated for the rework process, and the practice is to use a lot of it; so much of it that there is excessive residue and you need to remove it. The same goes for pen fluxes, which are also for rework. Most fluxes for wave soldering come in a 55-gallon drum, which is not something most end-users keep on the workbench!

In general, when performing handwork, you will need to clean the board unless no-clean is used, when doing reflow or wave soldering. If aesthetics are key, it’s important to clean. And, every kind of flux has its own specific flux remover. Some flux removers are broad spectrum. Most flux removers require flood cleaning; you need to use a substantial amount to effectively clean and wash a board. Simply squirting a tiny bit on does not work. It just leaves goop all over the board like a sticky film. You need to flood it on, let it soak for a few seconds, and in many cases, scrub with a brush. Then repeat the spray process to wash the “spent” material off the board. As a final process, let the board drip out and spray once more. If needed, apply warm air to dry. Never blow air using your mouth (human breath actually contains saliva, which is acidic). As the flux evaporates, it cools down the board which pulls moisture out of the air. Always use your reflow hot air gun for any type of final finishing and drying.

When it comes to technical cleaning, ACL Staticide manufactures top-quality rework and repair cleaning products and compliments, and QSource.com is your resource for all of them.

Thank you Steve, for that informative Guest Blog and for clearing up those flux cleaning myths. We look forward to your next blog submission.

For information about ACL Staticide and their related products, please visit our ACL Staticide Department at QSource.com. You may also contact us via email or phone at 800-966-6020 and one of our associates will be happy to assist you.



For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Friday, December 12, 2014

An Update on the HCFC-225 (AK-225) Phase Out & Ban – Guest Blog

by Steve Allen, VP Marketing and Innovation, ACL Staticide

Steve Allen's latest Guest Blog looks at the chemical replacements for AK-225 as it is approaches its total ban.

The EPA ban and elimination of HCFC-225 (also known as AK-225, and referred to that way from this point on) is a current topic of continuing concern in the area of electronics cleaning and printed circuit board (PCB) rework and repair. The banning of AK-225, effective January 1, 2015, will limit the number of available types of solvents for electronics cleaning. This will, once again, change the solvent cleaning landscape in our industry. It's important to understand what replacement chemistries will be available in 2015 and how this will affect end-users.

AK-225 falls under the EPA's Clean Air Act as a Class II ozone-depleting entity and is now defined as an Agency-Controlled Substance. It is thus deemed unlawful for any person to engage in interstate commerce of the solvent or any use of the substance unless it has been used, recovered, or recycled or used to produce another chemical, or finally, used as a refrigerant (until 1/1/2020). End-users may use, and continue to purchase, aerosols containing AK-225 made before January 1, 2015. Beginning January 1, 2015, AK-225 can only be used in the manufacture of end-user cleaning products if it has been used, recovered, and recycled, as per the Clean Air Act.

AK-225 (HCFC-225) is a cleaning solvent mixture of two isomers, HCFC-225ca and HCFC-225cb. AK-225 has many unique properties, including its ability to form azeotropes, strong solvency, and thermal stability, which makes it good for use in vapor degreasing. AK-225 is non-flammable, has a low acute toxicity, low viscosity, high density, and low surface tension. This list of great performance characteristics is what makes AK-225 such a great general-purpose precision-cleaning solvent. It is also why this particular solvent has been so difficult to replace with alternatives.

The Agency has approved more than 300 substitutes for multiple applications. Potential substitutes for AK-225 include DuPont Vertrel Solvents (Vertrel XF), n-Propyl Bromide (nPB), Trichloroethylene (TCE; mostly Chinese sources today), 3M hydrofluoroethers (HFEs), and Honeywell's Solstice Performance Fluid (Solstice PF).

DuPont's Vertrel has characteristics similar to AK-225, but is much more environmentally friendly. Solvents containing nPB work well for difficult precision-cleaning applications, but they are not considered environmentally friendly. From a health and environmental perspective, both nPB and TCE are not good replacements for AK-225 due to their low exposure limits and suspect carcinogenicity. The EPA is also currently evaluating the flammability limits of nPB. Additionally, TCE is an overly aggressive solvent making it unsuitable for use with most plastics and elastomers.

From an environmental standpoint 3M HFEs are great as they have been granted VOC exemption. Honeywell's HFO-1233zd(E) has a low global warming potential and is non-flammable. However, cost to the end-user for familiar cleaning applications may be an issue.

Because AK-225 is commonly used in high-end, Class 3 applications (like aerospace, medical, and biotech), qualification of replacement solvents is a difficult and complex process. It is not too early to start the process, and there are many choices to meet most every requirement. ACL Staticide has encouraged its end-use customers to initiate the replacement qualification process early to ensure solvent compatibility, performance, and product availability.

Considering all the facts and chemical replacement requirements from the EPA, ACL has developed a line of solvent chemistries and formulations designed specifically as AK-225 replacements. Our new line includes both flammable products and non-flammable products with our non-flammable alternatives developed specifically for AK-225. In particular, our new ACL 8624 A4 All Purpose Flux Remover & Cleaner has been formulated as a universal performance replacement for all former AK-225 applications. It has many of the same great features of AK-225, but without the ozone-depletion potential. It is recommended that the product be tested on plastics prior to use to determine plastic compatibility with each customer's unique application and process. Contact Q Source, Inc., your ACL Staticide distributor, at 800-966-6020 for more information regarding ACL's AK-225 replacements.

A big thank you to Steve, for another informative Guest Blog. We've appreciated your Q Source Resource contributions throughout this year and we look forward to more in 2015.

For information about ACL Staticide, or to purchase their related products, please visit our ACL Staticide Department at QSource.com. You may also contact us via email or phone (800-966-6020) and one of our associates will be happy to assist you.


For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Wednesday, November 5, 2014

More About the Basics of Flux in Electronics Soldering – Guest Blog

by Steve Allen, VP Marketing and Innovation, ACL Staticide

Steve Allen, from ACL, is back with a further discussion of the basics of flux in electronics soldering

For those of us associated with the electronics manufacturing industry, we are well aware that solder flux is a very important part of the soldering process. Flux is necessary to reduce the oxides that tend to form whenever you have hot metals in contact with the air. In electronics, we use a rosin-core solder, a mild no-clean solder, a more aggressive lead-free solder, or a water-soluble solder to aid the soldering process and eliminate metal oxides. We take great care regarding flux to make sure that we have selected a product that's not plumbing flux or acid-core flux because we know that will tend to corrode parts and components over time; they're okay for pipes but not for electronics.

In many cases, we're looking at rosin solder flux (in paste form) for most applications. If the temperature's a little bit colder, it will tend to crystallize and solidify. But it can be melted with a little bit of heat from the soldering iron. Of course, when you heat flux it tends to produce smoke, so it's good to have ventilation or a fume extractor to be sure that you're not breathing in the caustic vapors created from heating the flux. When you heat a work piece, flux reacts with the metal oxides that are forming with the temperature and exposure to the air. These residual metal oxides tend to interfere with the metal-forming process of soldering. Flux will chemically react with these oxides to make a nice, clean metal from the solder forming process that will form a pristine alloy on the board.

As we know, many solders come with flux in the core. The solder is actually hollow and inside the solder wire there is a central core of flux. As you feed the solder into your work piece, the flux then distributes itself over the surface of the work, reducing the formation of metal oxides and preventing them from occurring during soldering. Flux core solder can be helpful in many soldering instances for small, specific solder and repair projects. Additionally, we should talk about water-soluble flux, which is a recent and significant improvement in flux. With water-soluble flux, cleaning becomes easier. With rosin-core flux, the flux is not water-soluble. It takes an aggressive solvent cleaner to dissolve it and to remove it from the work piece. While easier to clean, water-soluble flux may not be appropriate in all circumstances. It can leave a residual layer that may interfere with high-impedance and high-resistance circuits where you have resistances (10 mega-ohms or greater). The water-based flux may actually lower that resistance and cause the circuit to malfunction.

Solder flux is an essential element when soldering, as it makes the soldering project much easier and of higher quality. Unfortunately, leaving even the no-clean fluxes behind on a PCB can cause some serious issues in circuit performance and even disable components. As part of the basics of flux, it's important that we understand what leaving flux on a PCB can do to your circuit.
Leaving fluxes behind can seriously damage a PCB.

In many instances, no-clean flux may not need to be cleaned from a circuit to prevent the flux from physically destroying the circuit. Unfortunately, the presence of flux changes the capacitance between traces, conductive pins, and circuits, and can ultimately get into the mechanical workings of electromechanical components and bind them up. Flux that requires cleaning is very acidic and can eat away at traces and pins, changing their resistance and even destroying surface mount components if the flux is left in place too long.

One particular location in board rework and repair, where the direct presence of residual flux has a significant impact, is on or near the input circuits to a differential input. Differential inputs are often balanced and used for very precise measurements. The presence of flux here will not only throw off any measurement, but can cause the readings to drift significantly over time.

Electromechanical components are also significantly impacted by flux. Often these components are soldered in by hand in the first few prototypes. The hand soldering of these components often works just fine, and the circuit moves on to an initial low-rate production run where problems start to occur in switches and other “mechanical-based” components. Often what happens is that the change in flux application techniques causes flux residue to build up inside the mechanical component and either prevents it from physically moving or makes the switch work intermittently. Troubleshooting these problems is extremely difficult and can lead to significant time loss during troubleshooting. This leads to quality problems we are trying to prevent.

Often when making prototypes components will be hand-soldered in place, circuits will be modified during testing, and parts will be replaced. Each of these operations requires the use of flux, which will need to be cleaned. ACL has developed a complete line of flux removers for all of these specific applications.

No Cleaning – If the circuit is slow, not susceptible to noise errors or increased DC offsets, then no cleaning could work just fine. However, for most circuits leaving the solder flux on the board will cause errors and make troubleshooting much more difficult.

Hand Cleaning – Better than no cleaning at all. Circuits see faster warmup periods and less current offset issues.

Soaking in an Aerosol Solvent Spray – Similar to hand cleaning, aerosol soak and rinse methods can be very helpful in cleaning out mechanical components where hand cleaning simply can't reach.

While it is tempting to save the 10 minutes or so and not perform a proper cleaning, for precision circuits, cleaning is an essential step in the testing and manufacturing process. Keeping a PCB board free of flux build up will save countless days in the testing and troubleshooting process and significantly reduce the stress of tracking down random errors and quality problems. Invest the money and time in an effective cleaner and cleaning process and spend more time building and designing great circuits (rather than countless hours troubleshooting problems).

Thanks Steve, for yet another Guest Blog full of must-have info that our Q Source Resource readers can apply to their own work environments.

For information about ACL Staticide and their related products, please visit our ACL Staticide Department at QSource.com.


For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Wednesday, June 11, 2014

How to Use the 80:20 Rule to Focus on the Business Innovation Process - Guest Blog

by Steve Allen, VP Marketing and Innovation, ACL Staticide
 

Our guest blogger, Steve Allen from ACL, looks at how to apply the Pareto Principle’s 80:20 rule in your business practices

"There is nothing quite so useless, as doing with great efficiency, something that should not be done at all."—Peter Drucker

Italian Economist Vilfredo Pareto
The Pareto Principle (also known as the 80:20 rule), irrespective of the nature of your business, holds that 80% of the consequences of any action come from 20% of the causes. This principle can actually be applied to everything you do. At ACL, we implement 80:20 simplification and rationalization disciplines into everything we do, including new product development and commercialization.

The original 80:20 observation is attributed to Italian economist Vilfredo Pareto who, in 1906, noticed that 80% of Italy's land was owned by 20% of the population. He then carried out surveys on a variety of other countries and found to his surprise that a similar distribution applied. He and others later discovered that this principle is proven in many other areas of interest:
  • 80% of results come from 20% of effort
  • 20% of your customers will account for 80% of your profit
  • 80% of your sales come from only 20% of your total product line
Apply the 80:20 rule to the information you receive: 20% is useful, whereas 80% is not. The key is to identify and focus on that 20% and ignore or remove the rest completely.

The same is true of time expended for results achieved. Think of the benefits of applying the Pareto Principle to your time management and personal and business productivity!

Which one of these statements rings true for your business?
  • 80% of your business comes from 20% of your customers
  • 20% of your product or service range contributes 80% of your sales and likely 90% of profits
  • 80% of customer complaints originate from 20% of the causes
  • 80% of your business productivity loss results from 20% of the causes
  • 80% of the value in the business is generated by 20% of the processes
The common approach to business is to squeeze every last drop out of each opportunity, to go "100% all-out," without consideration of the impact on time, productivity, and waste. Simple, time-efficient businesses recognize that it is fundamentally inefficient to go for the "whole pie" when you can get the majority of results for the minority of effort. With knowledge of the 80:20 lean simplification principles, you can concentrate on what wins you customers and successes in the most efficient manner and in the shortest amount of time. Look at your business and concentrate on the 20% that produces the 80% of benefit. Spend 80% of your time doing the 20% that really gets you results.

It’s not just about working smarter—it's about working smarter on the right things that will get you the best results. Pareto rules allow us to launch the products we know our customers need (such as the industry top-selling items offered in our new PCB Electronics Rework/Repair Production Chemicals line), and that our key distributor partners and sales teams can effectively sell. 80:20 gives us insight into developing value-added products that solve real problems for our customers.

Q Source, once again, thanks ACL Staticide’s Steve Allen for his Guest Blog contributions to The Q Source Resource.

For information about ACL Staticide products, please visit our ACL Staticide Department at QSource.com. You may also contact us via email or phone at 800-966-6020 and one of our associates will be happy to answer your questions or assist you with an order.

If there's a product or topic you'd like to see The Q Source Resource write about please let us know. We'd also appreciate if you share this blog post with your friends and colleagues via the social media links below. If you have questions or comments about the 80:20 rule or about ACL Staticide products please leave us a message in the comments section.

For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.

Steve Allen's Previous Guest Blogs

Wednesday, May 7, 2014

The Ergonomic Seating Solution: It Makes Dollars and Sense – Guest Blog

by Melinda Bohlmann, Bevco Precision Manufacturing Company

Melinda Bohlmann, our guest blogger from Bevco, writes about the health and financial benefits of providing workers with quality ergonomic seating.

You’ve seen the statistics. A report from the N.C. Department of Labor Occupational Safety and Health Program shows that almost 50% of workers in the industrial space suffer from back problems. Proper sitting contributes to the physical well-being of a worker and may add as much as 40 minutes of production to each workers day. The National Research Council and the Institute of Medicine estimate that nearly 1 million individuals in the United States lose time from work each year due to work-related musculoskeletal disorders (MSDs), with an associated $45-$54 billion annual cost.

Bevco offers a wide selection of high-quality ergonomic chairs
The evidence is staggering; the solution is clear. Having employees sit in the proper chair will not only save money (think lost time and medical expenses), but increase worker productivity. Who wouldn’t want that? Yet time after time we hear “I just need the cheapest chair you have.”

Let’s break it down. In this example, a company needs to purchase 100 chairs for their production facility. We’ll estimate that a good ergonomic chair costs $300 and an inexpensive, non-ergonomic chair costs $150. The ergonomic solution will cost $30,000 and the inexpensive solution will cost half that, $15,000. That seems like a lot of money to save, doesn’t it? Remember, looks can be deceiving.

In 2005, the U.S. Department of Labor determined that there were 4.6 injuries per 100 full-time employees in the workplace. Thirty percent of these injuries are due to low-back disorders. Injured employees required an average of 19 therapy visits (Worker’s Compensation Research Institute). A work-related injury resulted in an average loss of approximately $38,000 including wages, productivity loss, and medical expenses (National Safety Council, 2005).

Going back to our example—we’ll say that one employee suffers an MSD at an average loss of $38,000. If the facility went with the inexpensive chair solution they would have not only spent $15,000 for the chairs, but also an additional $38,000 to pay for the cost of the work-related injury—a total of $53,000. If the facility would have gone with the ergonomic solution they could have saved $23,000.

The ergonomic solution saves the most dollars…and makes the most sense. Not only for the bottom line, but also for the comfort and well-being of the employees.

Bevco has been a leading manufacturer of ergonomic seating for more than 60 years. Based in Waukesha, Wisconsin, Bevco offers a comprehensive line of seating for the industrial, laboratory, education, office, sewing, medical, and electronics market. The company is dedicated to providing customers with safe, ergonomic seating solutions that adhere to the highest quality regulations on the market.

Q Source would like to thank our guest blogger, Melinda Bohlmann. We appreciate your contribution to The Q Source Resource.




For additional Q Source product information, reviews, how-to articles, and special offers please subscribe to our email newsletter.